750 kVA – 1010 kVA

Features

Lowest OPEX: Best in class fuel efficiency with O2E technology
Lowest Footprint: Smallest footprint in this range while meeting the performance & CPCB II Norms
Modular Control System : Easily adapted to any configuration, viz standalone, interlocked, synchronised or grid connected
KOEL Green Alternator : Built on globally renowned design. Patented winding design helps withstand operating harsh conditions.
KRM : Critical genset parameters can be viewed on laptop or mobile
Customer Service: Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty: 2 years warranty* & labour free onsite service under warranty period

Description

India’s #1 Genset brand

KOEL GREEN is the market leader and India’s #1 Genset Brand . KOEL’s customised power solutions suit a wide range of 04applications, meetingprime power requirements. KOEL GREEN Gensets are available in sound resistant and environment friendly canopies. KOEL GREEN high horse power (HHP) range is spearheaded by SL90 and DV series. Upgraded with carefully selected technologies to meet latest CPCB emission norms, both SL90 and DV series Gensets are the most efficient machines delivering clean power to large requirements. Having best-in- class fuel economy, the performance capabilities are further enhanced with best-in- class block loading. KOEL Green HHP Gensets are extensively used in a variety of applications ranging from standard stand-alone Gensets to auto synchronized Gensets, special applications like Stone Crusher to Heat Exchanger cooled solutions for basement installations. KOEL Green is celebrating 30,000 HHP Genset sales, a testimony of superlative product performance in most demanding applications and customer’s trust in the range .

Best-in-class Fuel Efficiency10

KOEL Green Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, KOEL Green Gensets offer substantial savings in fuel cost.

O2E Series (Optimal Operanting Efficiency):

Genset rangs are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset.

In practice, Gensets rarely get loaded to full capacity. Power demand variations across day & night, weekdays & weekends.

Summer & winter lead to an average 50-70% loading on Gensets. Considering this practical situation, KOEL has extended fuel efficiency optimization from 100%, right up to 50% of rated load. Combination of best-in-class fuel efficiency & O2E provides a double advantage.

Genset Controls at your finger- tips11

There is no comfort like being in command. KOEL Green Gensets put the command in your hands. Micro-processor based Genset controllers display a host of Genset parameters and put all controls at your fingertips.

Monitoring Features
  • Phase Voltages & Currents, Frequency, Reverse power, Genset kVA, kW, kWh, kVAr, Power Factor, Canopy Temperature
  • Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop
  • Baery charge condion
  • AMF feature
Optional Features
  • Modbus communication, Synchronization, Remote Monitoring
Diagnostic Features
  • Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over kW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm
  • Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency

Peace-of-mind Ownership12

KOEL Green Gensets have always been preferred for their robust design and reliability over long usage life.
KOEL Green range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, KOEL has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability.
Thus, KOEL Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.

7-Days assured Delivery09

KOEL Chhota Chilli Gensets comes with a promise of assured delivery within 7 days of confirm order placement. Genset being a high value capital purchase may lead to needless block of capital and hence need not be purchased in advance. It is prudent to order the genset at the right time and plan the deliveries in line with your readiness to use. This will also avoid damages to genset due to lying unattended at site and engine re-validation cost.

Kirloskar Remote Monitoring system (KRM)

Your Genset now comes with complete remote monitoring control. Being in control of your own Genset is certainly a winning edge !

The KRM system links your Genset with a central monitoring data server through a SIM and internet. The complete monitoring panel with all critical indicators can be viewed on your laptop screen or mobile. You also get all alarms on your mobile phone.

Critical Parameters:

Genset Run hrs, Fuel level, Engine oil pressure, Engine temperature, Engine speed (RPM), voltage/ current/ kW, battery monitoring, PF & Frequency, routine maintenance indicator Critical Alarms: Low fuel level, low lub oil pressure, fuel theft, Engine speed, High Engine temperature, Mains On/ Off, Low/ High battery voltage.

Advantages of KRM system:

Your Genset will be used most efficiently as it’s health meter will always be available at your finger-tips. Being a ‘remote control’ this health monitoring can be done from wherever you are from the actual location of the Genset. This close monitoring also helps in reducing your operating costs and enhancing reliability of the Genset you own. So in all, you have better return on your investment and enhanced productivity by maximum uptime.

16

Product Specifications

Prime Rating at rated rpm (as per ISO8528 ) 1 kVA 320 HD 380 HD 400 HD 500 HD 600 HD 625 HD 750 HD 900 HD 1010 HD
kW 256 304 320 400 480 500 600 720 808
Genset Model KG1-320WS KG1-380WS KG1-400WS KG1-500WS KG1-600WS KG1-625WS KG1-750WS KG1-900WS KG1-1010WS
Frequency Hz 50 50 50 50 50 50 50 50 50
Power factor lagging 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Voltage (with Three Phase Supply ) V 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø
Governing class (As per ISO 8528 Part-V) G3 G3 G3 G3 G3 G3 G3 G3 G3
Noise level dBA < 75 < 75 < 75 < 75 < 75 < 75 < 75 < 75 NA
Fuel Consumption* At 100 % Load Ltrs/hr 69 83.3 86.9 107.5 125.9 130.5 154 197 199
At 75 % Load 52.5 61.2 65.099999999999994 81.900000000000006 94.2 98.6 126.4 163 155
At 50 % Load 37.6 44.1 46 57.1 63.8 66.2 89.7 120 112
Fuel tank capacity Ltrs 850 850 850 990 990 990 990 990 990
Weight of genset with Dry Kg 5910 6000 6050 7200 7700 7800 8300 13600 13200
canopy (approx.)^
Overall dimensions Length mm 5180 5446 5650 5650 6560 6560 6800 8000 7800
of genset Width mm 2000 2000 2000 2000 2000 2000 2300 2300 2300
Height mm 2408 2408 2408 2558 2710 2710 2713 2713 2713
Electrical Battery starting voltage Volts-DC 24 24 24 24 24 24 24 24 24
ENGINE
Engine Model DV8TA G1 DV8TA G2 DV8TA G3 DV10TA G1 DV12TA G1 DV12TA G2 DV12ETA G11 DV16ETA G2 DV16ETA G1
Rated output (Prime Continuous rating as kW 294 346 360 447 532 552 663 799 889
per ISO 3046) HP 400 470 490 608 723 750 901 1086 1210
No. of cylinder Number 8 8 8 10 12 12 12 16 16
Cubic capacity 2 Ltrs 15.92 15.92 15.92 19.899999999999999 23.88 23.88 23.88 31.86 31.86
Bore x Stroke mm 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150
Rated Speed RPM 1500 1500 1500 1500 1500 1500 1500 1500 1500
Aspiration NA/TC/TA TA TA TA TA TA TA TA TA TA
Lube Oil change period hrs 500 500 500 500 500 500 500 500 500
Lube Oil Sump Capacity Ltrs 44 44 44 50 53 53 53 130 130
Coolant Capacity with Radiator Ltrs 105 115 115 120 145 145 145 205 205
ALTERNATOR
Insulation Class Class H
Ingression Protection IP 23
Alternator Efficiency (at 100% load) 0.8 pf** 94.3 93.3 93.4 94.6 95 95 94.6 95.3 95.1
Alternator Efficiency (at 75% load) 0.8 pf** 93.8 93.8 94 94.9 95.2 95.2 94.9 95.5 95.4
Permissible Voltage Dip at Full Load 0.8 pf Lag < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 %
Time Permitted to build up rated voltage at rated RPM < 5 sec provided engine reach the rated speed
Short Circuit Withstand Time sec 3 Times Rated Current for “3 sec” 3 Times rated current for “10 sec “
Overload Withstand Capacity % 10% overload for one hour once in 12 hours